Corrosion is a common form of mechanical component failure. Below are some structural design examples to prevent corrosion.
I. Avoid narrow gaps
II. Prevent liquid accumulation in containers
III. Prevent rainwater accumulation at outdoor connection points
IV. Prevent contact between parts made of different materials
V. Ensure the structure facilitates disassembly and maintenance
VI. Prevent localized temperature differences within the container
VII. Prevent excessively high localized concentrations of the medium
VIII. Use butt joints for steel plate connections whenever possible, avoiding lap joints and riveting
IX. Avoid gaps in welds at right angles
X. Avoid sharp corners in flange connections